20
Options
99-186 Weatherhoods, Two - 6" c/w
1/4" mesh screen
99-130W Remote Wall Mount Dehumidistat
Control 24 VAC only
99-RSK6 6” back draft damper
99-104 DET - Digital Electronic Timer
Specifications Model CAF-U-00-36-P16
Core Ventilation system has patented aluminum heat recovery core (standard) or an enthalpic energy
recovery core (optional) for energy-efficient ventilation. Enthalpic cores are recommended for
regions where the temperature does not drop below 25˚F (-4˚C).
Filters Washable air filters in exhaust and supply air streams of ventilation section, 1" pleated in
return plenum side.
Case Prepainted galvanized steel for superior corrosion resistance.
Dimensions & Clearances
Note: Ventilation ports and
return plenum opening
available off either side of
cabinet. All units conform
to CSA and UL Standards.
Model CAF-U-00-36-P16
Voltage 120 VAC 60 Hz
Hp 1/2
Amps (total) 7.7
*
Airflow (High)
.25 in wg
1350 CFM
.5 in. wg 1180 CFM
Ventilation 100 - 140 CFM
Airflow
Effectiveness 70%
(Aluminum Core)
Total Efficiency 50%
(Enthalpic Core)
Net Weight 115 lbs.
Shipping Weight 130 lbs.
* Airflow performance assumes an evaporator
coil static pressure loss of .25”WC
Warranty
Units carry a lifetime warranty on the heat
recovery (aluminum) core, a five year warranty
on the energy recovery (enthalpic) core and a
five year replacement parts warranty on all
other components.
0211