Humidity levels are too low
1. If you have installed a dehumidistat ensure that
its setting is correct. (Summer - OFF) (Winter -
30% RH to 45% RH).
2. Check humidifier settings. (Summer - OFF)
(Winter - 30% RH to 45% RH).
NOTE: Humidifier should always be 10% lower
than dehumidistat.
3. Change thermostat fan switch from manual to
automatic.
Humidity levels are too high
1. If you have installed a dehumidistat ensure its
setting is correct. (Summer - OFF)(Winter -
30% RH to 45% RH).
2. Install a dehumidistat if necessary. (Winter use
only. Not for hot southern climates).
3. Change thermostat fan switch from automatic
to manual.
NOTE: The CAF has the ability to dehumidify dur-
ing the heating season. (When outside air is less
humid than indoor air). If you are in a region where
outdoor humidity levels are typically higher than
indoor humidity levels, a dehumidistat should not
be used in this system.